Control panel location
*9
Trigger key
Data storage
Dual-axis compensator / Collimation compensation
Reflectorless mode
:
Class 3R / Prism / sheet mode
:
Class 1
0.3 to 500m(1.0 to 1,640ft.)
RS90N-K: 1.3 to 500m (4.3 to 1,640ft.)
RS50N-K: 1.3 to 300m (4.3 to 980ft.), RS10N-K: 1.3 to 100m (4.3 to 320ft.)
Angle measurement
0.5" / 1"
(0.0001 / 0.0002gon, 0.002 / 0.005mil)
Display resolution
Accuracy (ISO 17123-3:2001)
IACS (Independent Angle Calibration System)
1"
2"
1" / 5"
(0.0002 / 0.001gon, 0.005 / 0.02mil)
3"
-
5"
7"
On one face
Provided
Dual-axis liquid tilt sensor, working range: ±6' (±111mgon) / Collimation compensation available
30x / 2.5"
30x / 3.5"
CX-101
CX-102
CX-103
CX-105
CX-107
Telescope
Magnification / Resolving power
Others
Length: 171mm (6.7in.), Objective aperture: 45mm (1.8in.) (48mm (1.9in.) for EDM), Image: Erect,
Field of view: 1°30' (26m/1,000m),Minimum focus: 1.3m (4.3ft.), Reticle illumination: 5 brightness levels
Display resolution
(3 + 2ppm x D) mm
*7
(3 + 2ppm x D) mm
(2 + 2ppm x D) mm
Accuracy
*2
(ISO 17123-4:2001)
(D=measuring distance in mm)
Interface and Data management
Measuring time
*8
Graphic LCD, 192 x 80 dots, backlight, contrast adjustment / Alphanumeric keyboard / 25 keys with backlight
On both faces
Fine: 0.9s (initial 1.7s), Rapid: 0.7s (initial 1.4s), Tracking: 0.3s (initial 1.4s)
Display / Keyboard
Bluetooth modem (option)
*10
Interface
On right instrument support
Approx. 10,000 points
USB flash memory (max. 8GB)
Serial RS-232C, USB2.0 (Type A, for USB flash memory)
Bluetooth Class 1, Ver.2.1+EDR, Operating range: up to 300m (980ft.)
*11
General
Laser-pointer
*12
Coaxial red laser using EDM beam
Guide light
*12
Levels
6’ (Inner Circle)
10' / 2mm
Optical plummet
Magnification: 3x, Minimum focus: 0.3m (11.8in.) from tribrach bottom
Laser plummet (option)
Red laser diode (635nm±10nm), Beam accuracy:
<
=
1.0mm@1.3m, Class 2 laser product
Dust and water protection
Operating temperature
*13
IP66 (IEC 60529:2001)
-20 to +60ºC (-4 to +140ºF)
Control panel on both faces: W191 x D181 x H348mm (W7.5 x D7.1 x H13.7in.)
Control panel on one face: W191 x D174 x H348mm (W7.5 x D6.9 x H13.7in.)
Approx.
5.6kg (12.3 lb.)
Power supply
Battery
Li-ion rechargeable battery
Operating time
(20
ºC
)
Approx. 36 hours (single distance measurement every 30 seconds)
BDC60: approx. 44 hours, BDC61: approx. 89 hours
(single distance measurement every 30 seconds)
Distance measurement
Reflectorless
*3
Reflective sheet
*4/*5
Mini prisms
One AP prism
Three AP prisms
Reflectorless
*3
Reflective sheet
*4
AP/CP prism
Internal memory
BDC70 detachable battery
BDC70
External battery
*14
(option)
Plug-in memory device
Graphic
Circular level
Model
CP01: 1.3 to 2,500m (8,200ft.), OR1PA: 1.3 to 500m (1,640ft.)
1.3 to 4,000m (4.3 to 13,120ft.) / Under good conditions
*6
: 5,000m (16,400ft.)
to 5,000m (16,400ft.) / Under good conditions
*6
: to 6,000m (19,680ft.)
Fine/Rapid: 0.001m / 0.01ft. / 1/8in. Tracking: 0.01m / 0.1ft. / 1/2in.
Laser output
*1
Measuring range
(under average conditions
*2
)
*1 IEC60825-1:Ed.2.0:2007 / FDA CDRH 21 CFR Part 1040.10 and 11 *2 Average conditions: Slight haze, visibility about 20km (12 miles), sunny periods, weak scintillation. *3 With Kodak Gray Card
White Side (90% reflective). When brightness on measured surface is 30,000 lx. or less. Reflectorless range/accuracy may vary according to measuring objects, observation situations and
environmental conditions. *4 When the measuring beam's incidence angle is within 30º in relation to the reflective sheet target. *5 Measuring range in temperatures of -30 to -20°C (-22 to -4°F) with
Low Temperature models
and 50 to 60°C (122 to 140°F):
RS90N-K: 1.3 to 300m (4.3 to 980ft.), RS50N-K: 1.3 to 180m (4.3 to 590ft.), RS10N-K: 1.3 to 60m (4.3 to 190ft.) *6 Good conditions: No
haze, visibility about 40km (25 miles), overcast, no scintillation. *7 Measuring range:0.3 to 200m *8 Typical, under good conditions. Reflectorless measurement time may vary according to measuring
objects, observation situations and environmental conditions. *9 Control panel location may vary depending on region or model. *10 Usage approval of Bluetooth wireless technology varies according
to country. Please consult your local office or representative in advance. *11 No obstacles, few vehicles or sources of radio emissions/interference in the near vicinity of the instrument, no rain. *12
The laser-pointer and the guide light do not work simultaneously. *13 Low Temperature models:-30 to 50 °C (-22 to 122°F) are available on built-to-order basis. *14 For CX-101, CX-102 and Low
temperature models.
CX-101/CX-102/CX-103/CX-105/CX-107
SPECIFICATIONS
C
X
Series
Tradition Meets Innovation
C
X
Series
Your local Authorized Dealer is:
Specifications subject to change without notice
©2012 Topcon Corporation All rights reserved. P-138-3 GE